Thursday

5 Basic Elements of Earth Fill Dams

A marvelous superstructure typically created by the placement and compaction of complex semi-plastic compositions of soil, sand, clay, or rock. Having semi-pervious waterproof natural covering for its natural surface and a dense, impervious core. Earthfill dam /  Embankment dam is a large artificial dam & also known as terrain dam. The typical cross-section of an earth fill dam shows a shape like a bank or a hill.

Some elements of Earth Fill Dams are listed below:
  1. Crest of Dam
The crest width of dams has to be adequate enough to maintain the seepage line inside the dam when the reservoir is filled to the brim. The top width of the dam if the road is not predicted and has to be of minimum 3m length for low and medium head dams and it has to be at least 6m for tall head dams. In cases where the road is envisaged, then the breadth of the dam is fixed in accordance with the class of road and is assessed on the basis of the road code.
Top width can be assessed with the help of the following commended formulae:
a) For highly low dams top width is specified by
B = H/5 + 3
b) For dams lesser than the length of 30m
B = 0.55(H)1/2 + H/5
For dams greater than the length of 30m
B = 1.65(H + 1.5)1/3
B = 1.67(H) 1/2
Balustrades are specified at the end of the roads to stop car falling off the slopes and cliffs.
  1. Side Slopes of the dam
Side slope of dams has to fulfill the static stability. But, since the stability computations could be undertaken only after stating the profile of the dam and fixing the seepage line, it becomes essential to provide an original side slope. The initial slope can be undertaken from the tables below:
SlopeMaterial of damSide slopes depending on the height of the dam
Less than 5mFrom 5m – 10mFrom 10-15m
UpstreamClayey
Sandy
2
2.5 – 2
2.5
3 – 2.5
3
3
Downstream
With filter
Clayey
Sandy
1.5
2
1.75
2
1.75
2
Downstream without filterClayey
Sandy
1.75
2
2
2.25
2.25
2.25
In the lower head dams, typically one and constant side slope is utilized, but in high head and medium dams, varying side slopes are typically utilized to decrease the size of the dam.
Side Slope Accordance to recommendations of Terzaghi
No.Kind of materialUpstream slope
(H: V)
Downstream slope (H: V)
1Well graded homogeneous soil2.5:12:1
2Homogeneous coarse silt3:12.5:1
3Homogeneous silt clay:
i) for dam height of maximum 15m
ii) for dam height greater than 15m
2.5:1
3:1
2:1
2.5:1
4Sand or sand and gravel with a clay core3:12.5:1
5Sand or sand and gravel with a reinforced concrete core wall2.5:12:1
  1. Berms: Berms are developed at both sides, the upstream and downstream side of the dam with the objective the states of assurances at the inclines and their repairs and furthermore to increase the width of a dam at the base with the point of expanding leakage length. It is additionally carried out when developments cofferdams are connected to the body of the dam. On the downstream side, berms are carried out an interim of 10 – 15m high. The breadth of the berm is taken between 1 – 2 m.
3. Free Board
Typical freeboard is the perpendicular space amongst the ordinary pool level and the apex of the dam. The least degree of the freeboard is the perpendicular separation between the high flood level and the peak of the dam.
The least stature of freeboard is undertaken as 1.5 hw where he is specified by:
how = 0.032 (V.F)1/2 + 0.763 – 0.271(F)1/4 for F, 32 km — –(X) Additionally, hw = 0.032 (V.F)1/2 for F . 32km — – (Y) where hw = wave tallness (stature of water from top to trough of waves in meters)
V = speed of twist in km/hr
F = bring or straight length of water breadth in km.
Freeboard values as recommended by U.S.B.R are specified in the table below:
Free Board by USBR
Spillway TypeDam Height in mMinimum freeboard over M.W.L
Free spillwayAny height2 m to 3 m
Controlled spillwayUp to 60 m2.5 m above the top of gate s
Controlled spillwayMore than 60 m3.0 m above the top of gates
  1. Slope Protection (Revetment)
Upstream side protection: For shielding the upstream slope from worsening and destruction from wave action, the slope is enclosed with diverse protective substances.
Rock riprap, it can be either dumped stone rocks or can be stone boulders could be constructed. Stone pitching gave a slope of 1.5: 1 to 2: 1 for regular soil material of dam and 3: 1 for poor soil material. The revetment stones are connected at the bottom of the dam to avoid the occurrence of slipping of the embankment. The density of the stone pitching is normally greater than 60 cm. In the majority of cases, the stone pitching is positioned over gravel and then sand cushion. Bigger sized stones with their broader face facing downwards are crammed with each other with the utilization of hammer.
Concrete, reinforced concrete slabs, steel plates, bituminous material pavement, brick tile pavement can also be favorably utilized. But, the widespread survey conducted by the US Corps of Engineers in the 1940s of over 100 dams have shown that dry dumped riprap stone pitching yields the best effectiveness in the basis of failure rate.

Upstream protection with hand-layered rip-rap
Downstream Protection
Planting green grass (turfs) is one of the most cost-effective, simple and operative approaches of defending the downstream from natural phenomena like rainfall and wind action. It should be carried out in slopes. Counter-boom can also be undertaken.
Downstream protection
  1. Drainage
Drainage in earth dams is implemented for bringing down the leakage bend; to prevent the leakage of water from streaming onto the downstream curve, and additionally passing on leakage water through the structure of the dam to the downstream part of the dam. By its characteristic, dam drainage should have at least 2 sections; a structure for intake (drainage trench) that permits leakage water from the body and base of the dam, while in the meantime steering clear of disfigurement courtesy of leakage and movement structure that vehicles that leak water from the dam. But, in most drainage, it is hard to see precisely these two sections.
Hydrotechnical construction development practice has worked out numerous drainage frameworks based upon the kind of dam, materials of the base and structure of the dam. Among the most regularly utilized drainage frameworks are:
i) Drainage crystal: with numerous positive sides (points of interest) however requires the utilization of expansive amount of stones
ii) A kind of drainage crystal in which the channel material of the drainage framework is laid to stretch out to a specific stature on the downstream façade. This kind of drainage framework is utilized when there could be the hike of the tailwater over the apex of the prism
iii) Flat even drainage: It needs a comparatively smaller amount of stones and rearranges construction. It has the benefit of depleting both the foundation and assortment of dam and it is utilized for the most part when the establishment is comprised of soaked material
iv) Combination of flat drain and prism
v) Horizontal channeled drainage: comprises of a pipe (tube), laid horizontal to base of the slant of dam.
vi) Horizontal stone drainage: a kind of level funneled drainage in which rather than the pipe, a stone prism is utilized.
Share it on:

earth filled dam meaning in Urdu

earthen dam pdf

types of dam

gravity dam

earthen dam ppt

rock fill dam

importance of dams

Tuesday

How to Do Analysis & Design OF G+5 Residential Building with Engineering Software?

Living in the 21st-century number of complicated and erratic structure and designed to endure the Earthquake, Wind and needs to analyze, design the structure by the various engineering software like ETABS, STAAD.Pro, TEKLA and to design the structure in this project we used the ETABS software due to company recommendation and to find stress analysis in slab, shear force for the beam and area reinforcement for the column and design the foundation depends upon the reaction and height of the foundation level depends upon site and safe bearing capacity of the soil due to stability purpose-designed the retaining wall in this project.

Keywords: Stress analysis, IS 875, Shear force, Bending moment, Deflection, Compression members.


 Preface of Engineering Software!

Marvelous structures & Landmarks are designed to resist the earthquake, wind load and stable the structure. Due to damage in the structure, it causes loss of peoples and venerability to the high rise buildings. To check the strength stiffness and resistance the displacement of the building by proper designs and detail. Extensile of the building is capable to design the proper gravity loads and depends on the design of the building, the analysis, the design is done by using the engineering software called E-TABS. ETABS is 3D structural software. ETABS is the abbreviation of "Extended 3D Analysis of Building System. Hence revisions are done depend upon the provisions and the result given by the analysis. Staad always gives higher demand for steel reinforcement. Also after proving the credibility of ETABS by manual calculations. Once correctly define materials in ETABS, and the necessary steps taken in the modeling process and discussed below.

The objective of Analysis Tools & Software

To perform the analysis and design of the structure without any type of failures.

1.      To understand the basic principles of structures by using  Standard Codes

2.      To understand the parameters of the design for beams, columns, slabs and other structural components.

3.      To prepare the 3D model of the structure by using the E-TABS Software for detailed analysis and design.

4.      To produce good structural work for performing analysis and design for a residential & any other kind of building.

Loads and Combination Formula

As per the limit state design of reinforced concrete structures and pre-stressed concrete structures, the following load combination has been taken:

1.      1.5(D.L+L.L)

2.      1.2(D.L+L.L±Ex)

3.      1.2(D/L+L.L±Ey)

4.      1.5(D.L±Ex)

5.      1.5(D.L±Ey)

6.      0.9D.l±1.5Ex

7.      0.9D.L±1.5Ey







For Example
The live load was taken as 2 KN/m2 since the analysis and design are being done for the residential building as per IS Code and as there is no need of giving Dead load in E-TABS which is an advantageous thing. Wall load for 9 inches is given as 12.42 KN/m2 and for inner walls 6.21 KN/m2. Floor finish was given as 0.8 KN/m2.

Material properties of the structure

A grade of concrete for the slab, beam, column: M20

Column Sizes = 230X350 mm

Beam Size = 230X350 mm

Slab thickness = 150 mm

Number of Stories = 5

Height = 3 meters and plinth height = 1.5 meters

Live Load on slab = 2 kN/sq.m. and Dead load on slab = 1.5 kN/sq.m.

Architectural plan

The plan was taken from the architecture in Lahore and been analyzed and designed by the software package E-TABS.

In fig 1 it shows the center line diagram of the building which is considered for analysis in ETABS.



                                                     Figure 1 Centre line diagram of the building

Methodology/Procedure

Step# 1: Initial setup of Standard Codes and Country codes

Step# 2: Creation of Grid points & Generation of structure

After getting opened with ETABS we select a new model and a window appears where we had entered the grid dimensions and story dimensions of our building.

Step# 3: Define the Property

Here we had first defined the material property by selecting define menu material properties. We add new material for our structural components (beams, columns, slabs) by giving the specified details in defining. After that, we define section size by selecting frame sections as shown below & added the required section for beams, columns etc.

Step# 4: Assign Property

After defining the property we draw the structural components using the command menu. Draw a line for the beam for beams and create columns in the region for columns by which property assigning is completed for beams and columns.

Step# 5: Assign Supports

By keeping the selection at the base of the structure and selecting all the columns we assigned supports by going to assign menu joint\frame Restraints (supports) fixed.

Step# 6: Defining Loads

In ETABS all the load considerations are first defined and then assigned. The loads in ETABS are defined as using static load cases command in define menu.

Step# 7: Assign Dead Loads

After defining all the loads. Dead loads are assigned for external walls, internal walls in the stand but in E-TABS automatically taken care by the software i.e., inbuilt

Step# 8: Assign Live loads

Live loads are assigned for the entire structure including floor finishing.

Step# 9: Assign wind loads

Wind loads are defined and assigned as per IS 875 1987 PART 3 by giving wind speed and wind angle. But since this is a G+3 Residential Building having a total height less than 12 meters there is no need of assigning of wind loads or earthquake loads.

Step# 10: Assign Seismic loads

Seismic loads are defined and assigned as per IS 1893: 2002 by giving zone, soil type, and response reduction factor in X and Y directions. But since this is a G+3 Residential Building having a total height less than 12 meters there is no need of assigning Seismic loads.

Step# 11: Assign load combinations

Using load combinations command in define menu 1.5 times of dead load and live load will be taken as mentioned in above.

Step# 12: Final Analysis

After the completion of all the above steps, we have performed the analysis and checked for errors.

Step# 13: Ready To Design

After the completion of the analysis, we had performed concrete design on the structure as per IS 456:2000. ETABS performs the designs for every structural element.



                                                   Figure 2 Model in ETABS

By using the centerline diagram the grid system is given by X and Y coordinates and spacing method of the grid system is adapted for convenient of the user.



Results of Example Structure’s Analysis

Shear Force for the analysis part

Shear and bending moment diagrams are analytical tools used in conjunction with structural analysis to help perform structural design by determining the value of shear force and bending moment at a given point of a structural element such as a beam.



                                 Figure 3 Shear force diagram for the structure



The bending moment diagram indicates the bending moment resisted by the beam.




                                Figure 4 Bending moment diagram for the structure



For the area of longitudinal reinforcement, go to design menu in ETABS, concrete frame design and start design check.





                                      Figure 5 Longitudinal reinforcement of the structure


Outcome of Analysis

The given structure is designed based on the E-TABS and the theory of LIMIT STATE METHOD which provide adequate strength, serviceability, and durability besides the economy. The displacement, shear force, bending moment variation has been shown. If any beam fails, the dimensions of the beam and column should be changed and reinforcement detailing can be produced.

Courtesy:
We are thankfull to 

K. Naga Sai Gopal 
B.Tech Student,  Civil Engg. Department, K L University, AP, India.

N. Lingeshwaran  
Assistant Professor Civil Engg. Department, K L University, AP, India.

AP, India.

To make that research publication Possible.

Found that article HELPFULL? Shear It On!

AddToAny